SW

Stormwater Directory

Compare Regulations

Compare city/county requirements side-by-side (up to 4 jurisdictions)

City of Brownsville(3 more)

Rows with an amber indicator differ across selections.

Field
Local
City of Brownsville
City of Brownsville Public Works / Engineering
Permit
Permit / AuthorizationGrading / Drainage Permit
Submit ToCity of Brownsville Public Works / Engineering
Lead TimePlan review typically 2–4 weeks
Application MethodSubmit via City of Brownsville Engineering at 1034 E. Levee St., Brownsville, TX 78520 or online portal at brownsvilletx.gov
FeeContact agency for current fee schedule
Water Quality
Impervious Cover LimitNo citywide impervious cover cap; drainage systems must accommodate design storm flows; resaca drainage system and Rio Grande proximity create unique constraints
On-Site Treatment RequiredNo
Detention RequiredYes — Detention required to limit post-development peak flows to pre-development levels for 2-, 10-, 25-, and 100-year storms per City of Brownsville Drainage Design Standards; flat Gulf Coastal Plain terrain requires pump-assisted drainage in some low areas
Turbidity / Discharge StandardNo numeric NTU limit; discharges must comply with TCEQ TXR150000 and not degrade Rio Grande, Brownsville Ship Channel, or Laguna Madre water quality; Rio Grande has international treaty water quality obligations
SWPPP
SWPPP / Local Plan RequiredYes — SWPPP per TCEQ TXR150000; drainage report required for local permit
PE Stamp RequiredYes
Inspections
Inspection RequirementsCity of Brownsville Public Works inspects grading permits at rough grading and final stabilization. Hurricane season preparedness required June–November.
Inspector QualificationNo city-specific certification required beyond TCEQ SWPPP requirements
Design & Zones
Local Design ManualCity of Brownsville Drainage Design Standards
Special Overlay ZonesRio Grande / IBWC Jurisdiction, Resaca System, Laguna Madre / Coastal Zone, FEMA Special Flood Hazard Area