SW

Stormwater Directory

Compare Regulations

Compare city/county requirements side-by-side (up to 4 jurisdictions)

City of Buda(3 more)

Rows with an amber indicator differ across selections.

Field
Local
City of Buda
City of Buda Development Services
Permit
Permit / AuthorizationGrading / Drainage Permit
Submit ToCity of Buda Development Services
Lead TimePlan review typically 2–4 weeks
Application MethodSubmit via City of Buda Development Services at 405 E. Loop St., Buda, TX 78610 or online portal at cityofbuda.com
FeeContact agency for current fee schedule
Water Quality
Impervious Cover LimitPortions of Buda are within the Edwards Aquifer Recharge Zone or Contributing Zone — EAA permit required; impervious cover caps (15% recharge zone / 30–65% contributing zone) apply on regulated sites
On-Site Treatment RequiredNo
Detention RequiredYes — Detention required to limit post-development peak flows to pre-development levels for 2-, 5-, 10-, 25-, and 100-year storms per City of Buda and Hays County Drainage Criteria
Turbidity / Discharge StandardNo numeric NTU limit; discharges must comply with TCEQ TXR150000 and not degrade Onion Creek, Garlic Creek, or Edwards Aquifer recharge features
SWPPP
SWPPP / Local Plan RequiredYes — SWPPP per TCEQ TXR150000; drainage report required for local permit
PE Stamp RequiredYes
Inspections
Inspection RequirementsCity of Buda Development Services inspects grading permits at rough grading and final stabilization.
Inspector QualificationNo city-specific certification required beyond TCEQ SWPPP requirements
Design & Zones
Local Design ManualCity of Buda Development Standards / Hays County Drainage Criteria
Special Overlay ZonesEdwards Aquifer Recharge and Contributing Zones, Onion Creek / Garlic Creek Floodplain