SW

Stormwater Directory

Compare Regulations

Compare city/county requirements side-by-side (up to 4 jurisdictions)

Edwards Aquifer Authority (Regional)(3 more)

Rows with an amber indicator differ across selections.

Field
Local
Edwards Aquifer Authority (Regional)
Edwards Aquifer Authority (EAA), San Antonio
Permit
Permit / AuthorizationEdwards Aquifer Protection Program (EAPP) Authorization
Submit ToEdwards Aquifer Authority (EAA), San Antonio
Lead Time30–60 days for Recharge Zone projects; Contributing Zone review may be faster; EAA recommends pre-application meeting
Application MethodPaper application to EAA offices (900 E. Quincy St., San Antonio); pre-application consultation strongly encouraged
FeeEAPP application fee: $500 base + acreage-based fee (ranges from ~$500 for small sites to $5,000+ for large developments); annual compliance inspection fee may apply
Water Quality
Impervious Cover LimitRecharge Zone: 15% max impervious cover (hard cap under EAA Rules); Contributing Zone: varies by subwatershed (typically 30–60%); Transition Zone: no EAA limit but local jurisdiction rules apply
On-Site Treatment RequiredYes
Detention RequiredYes — Recharge Zone: 100% of the 100-year, 24-hour storm must be retained on-site with no surface discharge to the aquifer recharge features (caves, sinkholes, losing streams); Contributing Zone: water quality volume must be captured and treated before discharge
Turbidity / Discharge StandardEAA prohibits discharges that could contaminate the aquifer; no numeric NTU limit but turbid discharges reaching recharge features are a violation; zero-discharge standard applies in Recharge Zone
SWPPP
SWPPP / Local Plan RequiredYes — EAA Best Management Practices (BMP) Plan — required as part of EAPP authorization
PE Stamp RequiredYes
Inspections
Inspection RequirementsEAA conducts site inspections during construction and post-construction in the Recharge Zone. Annual compliance reports required. TCEQ and EAA may conduct joint inspections for large projects.
Inspector QualificationPE-of-record responsible for BMP Plan compliance; no additional EAA-specific certification required, but familiarity with karst geology is strongly recommended
Design & Zones
Local Design ManualEAA Edwards Aquifer Protection Program Rules and Technical Guidance
Special Overlay ZonesEdwards Aquifer Recharge Zone, Edwards Aquifer Contributing Zone, Recharge Features (caves, sinkholes, losing streams)