SW

Stormwater Directory

Compare Regulations

Compare city/county requirements side-by-side (up to 4 jurisdictions)

City of Irving(3 more)

Rows with an amber indicator differ across selections.

Field
Local
City of Irving
City of Irving Development Services
Permit
Permit / AuthorizationGrading / Drainage Permit
Submit ToCity of Irving Development Services
Lead TimePlan review typically 2–4 weeks
Application MethodSubmit via City of Irving Building Inspections at 825 W. Irving Blvd., Irving, TX 75060 or online portal
FeeContact agency for current fee schedule
Water Quality
Impervious Cover LimitNo citywide impervious cover cap; drainage systems must accommodate design storm flows per Irving Drainage Design Criteria
On-Site Treatment RequiredNo
Detention RequiredYes — Detention required to limit post-development peak flows to pre-development levels for 2-, 10-, and 100-year storms per City of Irving Drainage Design Criteria Manual
Turbidity / Discharge StandardNo numeric NTU limit; discharges must comply with TCEQ TXR150000 and not degrade West Fork Trinity River, Elm Fork Trinity River, or Las Colinas canals
SWPPP
SWPPP / Local Plan RequiredYes — SWPPP per TCEQ TXR150000; drainage report required for local permit
PE Stamp RequiredYes
Inspections
Inspection RequirementsCity of Irving Development Services inspects grading permits at rough grading and final stabilization. Las Colinas canal system requires heightened protection during construction phases.
Inspector QualificationNo city-specific certification required beyond TCEQ SWPPP requirements
Design & Zones
Local Design ManualCity of Irving Drainage Design Criteria Manual
Special Overlay ZonesLas Colinas Canal Network, West Fork Trinity River Floodplain, DFW Airport Drainage Zone